Low E Insulation TAB

Low E Insulation TAB is pre-cut to specific widths (400mm or 600mm) for your convenience to neatly fit between rafters, studs, and joists. TAB is ideal for use in barn conversions, crawl spaces and basements where overlaying insulation is not possible.

Documentation

Download this as a PDF

Low-E Insulation Warranty Information Sheet

Download PDF

Download this as a PDF

Low-E Insulation COSHH Information Sheet

Download PDF

Download this as a PDF

Low-E Insulation TAB – Data Sheet

Download PDF

Low-E Insulation

Low-E Insulation TAB is our original reflective insulation product cut to specific widths for ease of install between rafters, studs and joists. Only 5.5mm thick Low-E Insulation acts not only as a superior air infiltration barrier, reducing draughts and uncontrolled air movement, but it also increases thermal performance by blocking up to 97% of radiant heat.

L4EFEC-15 [24] - Technical Details
Composition
Pure Aluminium / Recycled Foam / Pure Aluminium
Thickness
5.5mm
Width
416mm
Length
24m
Coverage
10m²
Weight
150g/m²
L4EFEC-10 [16] - Technical Details
Composition
Pure Aluminium/Recycled Foam/Pure Aluminium
Thickness
5.5mm
Width
625mm
Length
24m
Coverage
15m²
Weight
150g/m²
Composition
Pure Aluminium / Recycled Foam / Pure Aluminium
Thickness
5.5mm
Width
625mm
Length
24m
Coverage
15m²
Weight
150g/m²
Composition
Pure Aluminium/Recycled Foam/Pure Aluminium
Thickness
5.5mm
Width
416mm
Length
24m
Coverage
10m²
Weight
150g/m²

Technical Details 

Thermal Properties
Emissivity
0.05 (EN 16012)
Core Conductivity
0.0366 W/(mK)
Floor R-Value
1.92 (m²K/W)
Wall R-Value
1.65 (m²K/W)
Pitched Roof R-Value
1.43 (m²K/W)
Flat Roof R-Value
1.20 (m²K/W)
Fire/MVTR/Air Permeability
Fire Performance
Class 1 (BS 476)
MVTR
< 2000 (MN s/g)
Air Permeability
Additional Testing
Fungi/Mould Resistance
Pass
Sound Transmission (STC)
40 (ASTM E90)
Delamination
Pass
Corrosivity
Pass
Nail Tear
25-29 (N)
Tensile Strength
44.88-59.68 (N)
GWP
ZERO
Certification/Testing
LABC
Specialist Testing
Fire Test – Tent Fabric (ASTM 6413)
Pass
Fire Test – Tent Fabric (BS EN 5915)
Pass
Full Scale Room Burn
Emissivity (ASTM 1371)
0.03

Need a U-Value Calculation or Condensation Risk Analysis?

Our team are fully trained and here to help

Request a U-VALue

Browse Some Applications

Low-E Reflective Insulation can be used in virtually any application where environmental control is required.

Loft Insulation

Quick, clean and easy to install pitched roof insulation for maximum performance.

Pitched Roof Insulation

Reduce the thickness for your roof, install time and even the need for secondary insulation by using either Low-E EZY Seal Insulation or Low-E PERF on any pitched roof.
0/5 (0 Reviews)